logo
Good price online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Cable Fire Resistance Tester
Created with Pixso. High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2

High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2

Brand Name: GOLD
MOQ: 1 set
Price: USD 2000-6000
Delivery Time: 20 working days
Payment Terms: L/C,T/T
Detail Information
Place of Origin:
China
Certification:
ISO
Product:
Limiting Oxygen Index Tester
Standard:
ISO 4589-2
Application:
Cable Fire Resistance Test
Flow Meter:
160~1600L/H Adjustable
Pressure Gauge Accuracy:
2.5 Level
Resolution Of Oxygen Concentration Indicator:
0.1%
Packaging Details:
Plywood case
Supply Ability:
10 sets per month
Highlight:

high accuracy LOI Tester

,

LOI Tester ISO 4589-2

,

Limiting Oxygen Index Of Pvc

Product Description

Fire Resistance of Plastics: Limiting Oxygen Index (LOI) tester ISO 4589-2

 

Oxygen index refers to the minimum oxygen concentration required for a material to burn with a flame in an oxygen-nitrogen mixed gas flow under specific test conditions. It is expressed as a volume fraction and is an important indicator for evaluating the combustion performance of a material. The higher the limiting oxygen index, the more difficult the material is to burn. It is generally believed that materials above 27% are difficult to burn, and materials below 20% are flammable.

 

Principle and method of the Limiting Oxygen Index Tester:

1. Principle:

Under specified conditions, ignite the material in an oxygen-nitrogen mixed gas flow and measure the minimum oxygen concentration required to maintain its combustion.

2. Method:

Oxygen index meter: Use oxygen and nitrogen mixed in proportion, accurately control the gas flow rate, and measure the minimum oxygen concentration required to maintain the combustion of the sample.

3. Test standard:

Different materials and application scenarios have different test standards, such as ISO 4589-2 (room temperature oxygen index) and ISO 4589-3 (high temperature oxygen index).

 

Technical parameters:

  • Inner diameter of combustion tube 90mm.
  • Height of combustion tube 450mm.
  • Diameter of the tube hole at the tail end of the long rod igniter: φ2±1mm.
  • Flow meter: 160~1600L/H adjustable.
  • Pressure gauge accuracy is 2.5 levels.
  • Pressure gauge resolution: 0.01MPa.
  • Resolution of oxygen concentration indicator: 0.1%.
  • Oxygen sensor: High-precision oxygen sensor imported from Germany.
  • Gas source: Oxygen specified in GB3863, nitrogen specified in GB3864.
  • Test environment: temperature 10-35℃, humidity 45-75%.
  • Input pressure: 0.2- 0.3MPa.
  • Working pressure: 0.05- 0.15MPa.
  • Sample type: self-supporting material and non-self-supporting material.

High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2 0

High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2 1

Specification:

Control box dimensions

460mm(L)×420mm(W)×760mm(H);

Combustion tube base dimensions

250mm×250mm×550mm;

Power supply

AC220V, 50/60Hz, DC 1A;

Gas source

 oxygen, nitrogen (provided by the customer).

 

Good price online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Cable Fire Resistance Tester
Created with Pixso. High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2

High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2

Brand Name: GOLD
MOQ: 1 set
Price: USD 2000-6000
Packaging Details: Plywood case
Payment Terms: L/C,T/T
Detail Information
Place of Origin:
China
Brand Name:
GOLD
Certification:
ISO
Product:
Limiting Oxygen Index Tester
Standard:
ISO 4589-2
Application:
Cable Fire Resistance Test
Flow Meter:
160~1600L/H Adjustable
Pressure Gauge Accuracy:
2.5 Level
Resolution Of Oxygen Concentration Indicator:
0.1%
Minimum Order Quantity:
1 set
Price:
USD 2000-6000
Packaging Details:
Plywood case
Delivery Time:
20 working days
Payment Terms:
L/C,T/T
Supply Ability:
10 sets per month
Highlight:

high accuracy LOI Tester

,

LOI Tester ISO 4589-2

,

Limiting Oxygen Index Of Pvc

Product Description

Fire Resistance of Plastics: Limiting Oxygen Index (LOI) tester ISO 4589-2

 

Oxygen index refers to the minimum oxygen concentration required for a material to burn with a flame in an oxygen-nitrogen mixed gas flow under specific test conditions. It is expressed as a volume fraction and is an important indicator for evaluating the combustion performance of a material. The higher the limiting oxygen index, the more difficult the material is to burn. It is generally believed that materials above 27% are difficult to burn, and materials below 20% are flammable.

 

Principle and method of the Limiting Oxygen Index Tester:

1. Principle:

Under specified conditions, ignite the material in an oxygen-nitrogen mixed gas flow and measure the minimum oxygen concentration required to maintain its combustion.

2. Method:

Oxygen index meter: Use oxygen and nitrogen mixed in proportion, accurately control the gas flow rate, and measure the minimum oxygen concentration required to maintain the combustion of the sample.

3. Test standard:

Different materials and application scenarios have different test standards, such as ISO 4589-2 (room temperature oxygen index) and ISO 4589-3 (high temperature oxygen index).

 

Technical parameters:

  • Inner diameter of combustion tube 90mm.
  • Height of combustion tube 450mm.
  • Diameter of the tube hole at the tail end of the long rod igniter: φ2±1mm.
  • Flow meter: 160~1600L/H adjustable.
  • Pressure gauge accuracy is 2.5 levels.
  • Pressure gauge resolution: 0.01MPa.
  • Resolution of oxygen concentration indicator: 0.1%.
  • Oxygen sensor: High-precision oxygen sensor imported from Germany.
  • Gas source: Oxygen specified in GB3863, nitrogen specified in GB3864.
  • Test environment: temperature 10-35℃, humidity 45-75%.
  • Input pressure: 0.2- 0.3MPa.
  • Working pressure: 0.05- 0.15MPa.
  • Sample type: self-supporting material and non-self-supporting material.

High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2 0

High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2 1

Specification:

Control box dimensions

460mm(L)×420mm(W)×760mm(H);

Combustion tube base dimensions

250mm×250mm×550mm;

Power supply

AC220V, 50/60Hz, DC 1A;

Gas source

 oxygen, nitrogen (provided by the customer).