Brand Name: | GOLD |
MOQ: | 1 set |
Price: | 3000-6000 |
Delivery Time: | 25 working days |
Payment Terms: | L/C,T/T |
EN ISO 1182 Building Materials Non Combustibility Test Apparatus
EN ISO 1182 Building Materials Non Combustibility Test Apparatus - Scope of application
This test method for evaluating the combustion performance of building materials under laboratory conditions. For composite products, each component material of the product can be tested separately and explained in the test report. This test is related to the A1, A2, A1f1, and A2 f1 ratings in the building product classification.
EN ISO 1182 Building Materials Non Combustibility Test Apparatus - Test method
The sample is placed in the furnace, the thermocouple is inserted into the center of the sample, and the test equipment is connected. The exposure temperature is 750°C and the test time is 20 minutes. The thermocouple temperature and burning time are recorded during the test.
EN ISO 1182 Building Materials Non Combustibility Test Apparatus - result evaluation
According to EN1182, the "combustibility" or "non-combustibility" of materials is evaluated according to the following provisions:
The average temperature rise in the furnace should not exceed 50°C, and the calculated average duration of the flame should not exceed 20S
After cooling, the average mass loss should not exceed 50% of the average initial mass
Introduction:
Non-combustible material refers to a material that is heated by fire even in the event of fire, even if it is burned red or melted. The non-combustibility tester is developed according to ISO 1182 and GB/T 5464 non-combustibility test method for building materials. Main application The non-combustibility test method for building materials is suitable for testing the burning performance classification of Class A fireproof materials in the burning performance classification of building materials GB 8624. The non-combustible test furnace can be applied to composite products as well as to the materials of the components constituting the product. The non-combustibility tester can also be applied to the fire test of British building materials, railway locomotive materials and non-metal products. The non-combustibility tester test data includes the temperature rise in the furnace, the thermal weight loss of the test sample, and the ignition time of the sample.
Features:
Specification:
Heating furnace dimensions |
400mm(W)*400mm(D)*1400(H) |
Control chamber dimension |
430mm(W)*450mm(D)*300mm(H) |
Power |
AC 220V, 50/60Hz, 10A |
Weight |
about 50kg |
Brand Name: | GOLD |
MOQ: | 1 set |
Price: | 3000-6000 |
Packaging Details: | Exported standard packaging |
Payment Terms: | L/C,T/T |
EN ISO 1182 Building Materials Non Combustibility Test Apparatus
EN ISO 1182 Building Materials Non Combustibility Test Apparatus - Scope of application
This test method for evaluating the combustion performance of building materials under laboratory conditions. For composite products, each component material of the product can be tested separately and explained in the test report. This test is related to the A1, A2, A1f1, and A2 f1 ratings in the building product classification.
EN ISO 1182 Building Materials Non Combustibility Test Apparatus - Test method
The sample is placed in the furnace, the thermocouple is inserted into the center of the sample, and the test equipment is connected. The exposure temperature is 750°C and the test time is 20 minutes. The thermocouple temperature and burning time are recorded during the test.
EN ISO 1182 Building Materials Non Combustibility Test Apparatus - result evaluation
According to EN1182, the "combustibility" or "non-combustibility" of materials is evaluated according to the following provisions:
The average temperature rise in the furnace should not exceed 50°C, and the calculated average duration of the flame should not exceed 20S
After cooling, the average mass loss should not exceed 50% of the average initial mass
Introduction:
Non-combustible material refers to a material that is heated by fire even in the event of fire, even if it is burned red or melted. The non-combustibility tester is developed according to ISO 1182 and GB/T 5464 non-combustibility test method for building materials. Main application The non-combustibility test method for building materials is suitable for testing the burning performance classification of Class A fireproof materials in the burning performance classification of building materials GB 8624. The non-combustible test furnace can be applied to composite products as well as to the materials of the components constituting the product. The non-combustibility tester can also be applied to the fire test of British building materials, railway locomotive materials and non-metal products. The non-combustibility tester test data includes the temperature rise in the furnace, the thermal weight loss of the test sample, and the ignition time of the sample.
Features:
Specification:
Heating furnace dimensions |
400mm(W)*400mm(D)*1400(H) |
Control chamber dimension |
430mm(W)*450mm(D)*300mm(H) |
Power |
AC 220V, 50/60Hz, 10A |
Weight |
about 50kg |