Cone Calorimeter
Created with Pixso. Building Materials Flame Retardant Test ISO 5660 ASTM E1354 Cone Calorimeter

Building Materials Flame Retardant Test ISO 5660 ASTM E1354 Cone Calorimeter

Brand Name: GOLD
Model Number: GD-ISO 5660
MOQ: 1
Price: USD 10000-15000/set
Delivery Time: 30 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Detail Information
Place of Origin:
China
Certification:
ISO
Product Name:
ISO 5660 Cone Calorimeter
Standard:
ISO 5660, ASTM D1354, BS 476-15
Cone Heater:
0~100kW/m2
Size:
1,800 Mm(W)*900 Mm(D)*2,650 Mm(H)
Oxygen Analyzer,:
Paramagnetic Type
Sample Box Size:
100mm X 100mm X 50mm
Exhaust:
50 L/s
Utilities:
Compressed Air, Methane, Nitrogen, CO/CO2 Mixing Gas, Dust Collector
Packaging Details:
Plywood case
Supply Ability:
5 sets per month
Highlight:

Building Materials Flame Retardant Test

,

Flame Retardant Test Cone Calorimeter

,

ASTM E1354 Cone Calorimeter

Product Description

Building Materials Flame Retardant Test ISO 5660 ASTM E 1354 Cone Calorimeter

 

 

ISO 5660 Cone Calorimeter Product introduction:

 

Heat release rate is a key performance indicator for evaluating the fire hazard of materials and products. As an internationally used test equipment, the cone calorimeter fully complies with the current major fire test standards and specifications (including ISO 5660 series, ASTM E1354, ASTM E1474, ASTM E1740, ASTM F1550, ASTM D6113, NFPA 264, CAN/ULC-S135 and BS 476-15, etc.). Its test principle is based on the basic thermochemical law of oxygen consumption method: there is a quantitative relationship between the heat released by material combustion and the oxygen consumption, and each kilogram of oxygen consumed corresponds to the release of approximately 13.1 megajoules of heat. During the test, the instrument accurately monitors a number of key parameters: real-time heat release rate, ignition time, oxygen concentration changes, carbon monoxide and carbon dioxide production rates, smoke generation and exhaust flow, etc. These data together constitute a complete evaluation system for the combustion characteristics of the material.

 

ISO 5660 Cone Calorimeter Test Standards:

 

• ISO 5660: Tests for reaction to fire - heat release rate, smoke generation rate and mass loss rate
• ASTM E 1354: Standard test method for heat and visible smoke release rate of materials
• BS 476 Pt.15: Testing of building materials and building structures: – Methods for testing the heat release rate of products
• GB/T 16172-2007 Test method for heat release rate of building materials
• NFPA 264

 

ISO 5660 Cone Calorimeter Structure Feature:

 

1. 19-inch standard cabinet integrated design, beautiful and easy to operate
2. Conical heater - in a truncated cone, 230V, 5000W, heat output is 0~120 kW/m2
3. 19" touch screen computer controls the entire test process
4. Automatic ignition system, automatic measurement of burning time
5. 3 K-type thermocouples and 3-phase PID temperature controller to regulate temperature
6. Automatic split gate - protect the sample area before testing, ensure the stability of initial quality measurement, and the operator can have extra time to perform system inspection before the test starts. For flammable samples, if there is no opening and closing mechanism, it is easy to burn prematurely. This extra time is very important for the operator
7. Sample holder - sample size 100mm x 100mm, thickness not exceeding 50mm;

 

Building Materials Flame Retardant Test ISO 5660 ASTM E1354 Cone Calorimeter 0

ISO 5660  Cone Calorimeter Specification:

 

Product name
Cone Calorimeter
Standard
ISO 5660, ASTM D1354, BS 476-15
Size
1,800 mm(W)*900 mm(D)*2,650 mm(H)
Power
220 V AC, 50/60 Hz, 30 A
Weight
about 450 kg
Manual
Supplied
Exhaust
50 l/s
Utilities
Compressed Air, Methane, Nitrogen, CO/CO2 Mixing Gas, Dust Collector

 

Building Materials Flame Retardant Test ISO 5660 ASTM E1354 Cone Calorimeter 1

 

Ignition system:

 

1. 10kV spark igniter, equipped with a safety stop device. The igniter is automatically positioned by a lever connected to the closing mechanism
2. The system automatically ignites; automatically times; automatically shuts off the gas and flames out

 

Exhaust system:

 

1. It is composed of axial flow fan, stainless steel exhaust pipe, diffusion plate, smoke hood, exhaust pipe, orifice flowmeter and thermometer;
2. It is made of stainless steel to extend the service life. Including hood, gas sample sampling needle, exhaust fan

 

Gas sampling system:


1. Including annular sampler, suction pump, particulate filter, cold trap, exhaust valve, moisture filter and CO2 filter
2. Three-stage filter; filtration accuracy 0.5um
3. Refrigerated cold trap; compressor air conditioning refrigeration system; control temperature 0~5℃
4. The sampler has 12 small holes opposite to the airflow direction; built-in smoke filter; 685mm away from the smoke hood

 

Measurement system:

 

1. Paramagnetic oxygen analyzer, range 0-25%; imported British Servomex oxygen sensor; linear response;
2. Use laser system to measure smoke density,
3. Use high-precision load-bearing sensor to measure the weight change of the test material during the test process.
4. Temperature control system: PID temperature control, 3 thermocouples to measure the temperature of the radiation cone

 

User operating system:


1. Labwiew control system for experimental instruments, with friendly interface, easy operation and precise control;
2. PID temperature control module is linked with power adjustment module, and constant temperature adjustment is performed through programmable controller control;
3. Signal acquisition and processing module is linked with air volume circuit control module, and preset wind speed is intelligently adjusted through programmable controller logic calculation output;
4. The system provides query function. The system automatically stores the number, temperature curve and data of the test sample into the database in the system; and the number of the sample being tested, test date, etc. can be entered for query.

 

Building Materials Flame Retardant Test ISO 5660 ASTM E1354 Cone Calorimeter 2

Good price online

Products Details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Cone Calorimeter
Created with Pixso. Building Materials Flame Retardant Test ISO 5660 ASTM E1354 Cone Calorimeter

Building Materials Flame Retardant Test ISO 5660 ASTM E1354 Cone Calorimeter

Brand Name: GOLD
Model Number: GD-ISO 5660
MOQ: 1
Price: USD 10000-15000/set
Packaging Details: Plywood case
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Detail Information
Place of Origin:
China
Brand Name:
GOLD
Certification:
ISO
Model Number:
GD-ISO 5660
Product Name:
ISO 5660 Cone Calorimeter
Standard:
ISO 5660, ASTM D1354, BS 476-15
Cone Heater:
0~100kW/m2
Size:
1,800 Mm(W)*900 Mm(D)*2,650 Mm(H)
Oxygen Analyzer,:
Paramagnetic Type
Sample Box Size:
100mm X 100mm X 50mm
Exhaust:
50 L/s
Utilities:
Compressed Air, Methane, Nitrogen, CO/CO2 Mixing Gas, Dust Collector
Minimum Order Quantity:
1
Price:
USD 10000-15000/set
Packaging Details:
Plywood case
Delivery Time:
30 days
Payment Terms:
L/C, D/A, D/P, T/T, Western Union
Supply Ability:
5 sets per month
Highlight:

Building Materials Flame Retardant Test

,

Flame Retardant Test Cone Calorimeter

,

ASTM E1354 Cone Calorimeter

Product Description

Building Materials Flame Retardant Test ISO 5660 ASTM E 1354 Cone Calorimeter

 

 

ISO 5660 Cone Calorimeter Product introduction:

 

Heat release rate is a key performance indicator for evaluating the fire hazard of materials and products. As an internationally used test equipment, the cone calorimeter fully complies with the current major fire test standards and specifications (including ISO 5660 series, ASTM E1354, ASTM E1474, ASTM E1740, ASTM F1550, ASTM D6113, NFPA 264, CAN/ULC-S135 and BS 476-15, etc.). Its test principle is based on the basic thermochemical law of oxygen consumption method: there is a quantitative relationship between the heat released by material combustion and the oxygen consumption, and each kilogram of oxygen consumed corresponds to the release of approximately 13.1 megajoules of heat. During the test, the instrument accurately monitors a number of key parameters: real-time heat release rate, ignition time, oxygen concentration changes, carbon monoxide and carbon dioxide production rates, smoke generation and exhaust flow, etc. These data together constitute a complete evaluation system for the combustion characteristics of the material.

 

ISO 5660 Cone Calorimeter Test Standards:

 

• ISO 5660: Tests for reaction to fire - heat release rate, smoke generation rate and mass loss rate
• ASTM E 1354: Standard test method for heat and visible smoke release rate of materials
• BS 476 Pt.15: Testing of building materials and building structures: – Methods for testing the heat release rate of products
• GB/T 16172-2007 Test method for heat release rate of building materials
• NFPA 264

 

ISO 5660 Cone Calorimeter Structure Feature:

 

1. 19-inch standard cabinet integrated design, beautiful and easy to operate
2. Conical heater - in a truncated cone, 230V, 5000W, heat output is 0~120 kW/m2
3. 19" touch screen computer controls the entire test process
4. Automatic ignition system, automatic measurement of burning time
5. 3 K-type thermocouples and 3-phase PID temperature controller to regulate temperature
6. Automatic split gate - protect the sample area before testing, ensure the stability of initial quality measurement, and the operator can have extra time to perform system inspection before the test starts. For flammable samples, if there is no opening and closing mechanism, it is easy to burn prematurely. This extra time is very important for the operator
7. Sample holder - sample size 100mm x 100mm, thickness not exceeding 50mm;

 

Building Materials Flame Retardant Test ISO 5660 ASTM E1354 Cone Calorimeter 0

ISO 5660  Cone Calorimeter Specification:

 

Product name
Cone Calorimeter
Standard
ISO 5660, ASTM D1354, BS 476-15
Size
1,800 mm(W)*900 mm(D)*2,650 mm(H)
Power
220 V AC, 50/60 Hz, 30 A
Weight
about 450 kg
Manual
Supplied
Exhaust
50 l/s
Utilities
Compressed Air, Methane, Nitrogen, CO/CO2 Mixing Gas, Dust Collector

 

Building Materials Flame Retardant Test ISO 5660 ASTM E1354 Cone Calorimeter 1

 

Ignition system:

 

1. 10kV spark igniter, equipped with a safety stop device. The igniter is automatically positioned by a lever connected to the closing mechanism
2. The system automatically ignites; automatically times; automatically shuts off the gas and flames out

 

Exhaust system:

 

1. It is composed of axial flow fan, stainless steel exhaust pipe, diffusion plate, smoke hood, exhaust pipe, orifice flowmeter and thermometer;
2. It is made of stainless steel to extend the service life. Including hood, gas sample sampling needle, exhaust fan

 

Gas sampling system:


1. Including annular sampler, suction pump, particulate filter, cold trap, exhaust valve, moisture filter and CO2 filter
2. Three-stage filter; filtration accuracy 0.5um
3. Refrigerated cold trap; compressor air conditioning refrigeration system; control temperature 0~5℃
4. The sampler has 12 small holes opposite to the airflow direction; built-in smoke filter; 685mm away from the smoke hood

 

Measurement system:

 

1. Paramagnetic oxygen analyzer, range 0-25%; imported British Servomex oxygen sensor; linear response;
2. Use laser system to measure smoke density,
3. Use high-precision load-bearing sensor to measure the weight change of the test material during the test process.
4. Temperature control system: PID temperature control, 3 thermocouples to measure the temperature of the radiation cone

 

User operating system:


1. Labwiew control system for experimental instruments, with friendly interface, easy operation and precise control;
2. PID temperature control module is linked with power adjustment module, and constant temperature adjustment is performed through programmable controller control;
3. Signal acquisition and processing module is linked with air volume circuit control module, and preset wind speed is intelligently adjusted through programmable controller logic calculation output;
4. The system provides query function. The system automatically stores the number, temperature curve and data of the test sample into the database in the system; and the number of the sample being tested, test date, etc. can be entered for query.

 

Building Materials Flame Retardant Test ISO 5660 ASTM E1354 Cone Calorimeter 2