Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Flame Spread Test
Created with Pixso. ISO 12468-1 Roof External Fire Exposure Testing Machine for Building Materials

ISO 12468-1 Roof External Fire Exposure Testing Machine for Building Materials

Brand Name: Gold
Model Number: GD-ISO12468
MOQ: 1
Price: negotiation
Delivery Time: 45 work days
Payment Terms: L/C,D/A,T/T,D/P,Western Union
Detail Information
Place of Origin:
China
Certification:
ISO
Name:
Roof External Fire Exposure Testing Machine
Standard:
ISO12468-1
Application:
Roof Material
Test Categories:
Heat Radiant Spread Test
Gas Require:
Methane And Pure Oxygen
Environmental Requirements:
Temperature: 10~35℃ (60 To 85℉), Humidity: 45%~75%.
Packaging Details:
plywood box
Supply Ability:
1 per 45 works day
Highlight:

ISO 12468-1 roof fire testing machine

,

building materials fire exposure tester

,

external flame spread test equipment

Product Description
ISO 12468-1 Roof External Fire Exposure Testing Machine for Building Materials
The Roof External Fire Exposure Tester is a precision testing device specifically designed to evaluate the fire resistance of roofing materials and systems under external fire conditions. It strictly complies with leading international standards including ISO 12468-1:2013, CEN/TS 1187:2012, ASTM E108, and EN 13501-5.
This equipment accurately tests flame propagation, penetration, and combustion behavior of roofing materials under real fire conditions by simulating various external fire source scenarios, including flame propagation, flame spread, wind-assisted flame, and radiant heat.
ISO 12468-1  Roof External Fire Exposure Testing Machine for Building Materials 0
Compliance Standards
ISO 12468-1:2013 - External exposure of roofs to fire -- Part 1: Test method
CEN/TS 1187:2012 - Test methods for external fire exposure to roofs
DD ENV 1187:2002 - Test methods for external fire exposure to roofs
ASTM E108-20a - Standard Test Methods for Fire Tests of Roof Coverings
UL 790 Ed. 9-2022 - Standard Test Methods for Fire Tests of Roof Coverings
EN 13501-5:2016 - Fire classification using data from external fire exposure to roofs tests
Test Product Applications
Asphalt Shingles (Organic or Fiberglass Based)
Fiberglass Reinforced Asphalt Shingles
Wood Shakes
Wood Shingles
Clay Sheets (Flat or Curved)
Concrete Sheets
Slate Sheets (Natural or Synthetic)
Metal Roofing Sheets (Steel, Aluminum, Copper, or Zinc)
Built-Up Roofing Systems
Modified Bituminous Sheets (SBS or APP Polymer Modified)
Single-Layer Thermoplastic Polyolefin Sheets (TPO)
Single-Layer Ethylene Propylene Diene Monomer (EPDM) Sheets
Single-Layer Polyvinyl Chloride (PVC) Sheets
Liquid Coated Roofing (Acrylic, Silicone, or Polyurethane Based)
Green Vegetation Roofing Systems
Integrated Photovoltaic Roofing Panels
Foam Insulation Roofing Panels (Polystyrene or Polyisocyanurate Core)
Corrugated Fiber Cement Board
Thatch Roofing Materials (Straw or Reed Based)
Composite Roofing Panels (Polymer or Recycled Material Mixture)
Technical Parameters
Parameter Specification
Test specimen rack structure Constructed from welded metal square tubing and angle steel
Test specimen rack angle adjustment Automatically adjustable to different angles
Test rack angle adjustment range 0-50 degrees
Duct material SUS304 stainless steel, 2 mm thick
Fan Maximum fan speed of 15000 m³/h
Fan adjustment Variable frequency drive, automatically adjusted by computer. Power: 5.5KW
Air duct drive system Ball screw and servo motor drive
Adjustable angle range of air duct 0-35 degrees
Wind speed measurement 7 different positions on sample surface using anemometer
Anemometer accuracy 0.1 m/s
Radiation plate dimensions (600±10) mm * (60±10) mm
Heat flux measurement range (0~50) KW/m², accuracy ±3%
Ignition device Support frame and igniter with gas burner
Flame temperature 900℃ ± 50℃ at 60mm ± 5mm above burner
Additional equipment One set of woodpile fire gas combustion device; Two sets of video monitoring devices