| ব্র্যান্ড নাম: | GOLD |
| মডেল নম্বর: | জিডি-এফএএ |
| MOQ: | 1 সেট |
| দাম: | USD 6000-9000 |
| বিতরণ সময়: | 15 কার্যদিবস |
| অর্থ প্রদানের শর্তাবলী: | এল/সি, টি/টি |
The FAA Aviation Material Combustion Test Chamber is a flame-retardant performance testing device specifically designed for non-metallic materials used in aircraft cabins. This equipment strictly adheres to the relevant testing standards of the U.S. Federal Aviation Administration (FAA) and has also obtained domestic civil aviation airworthiness certification approval, making it an Aviation Material Combustion Test Chamber that combines international authority with domestic compliance.
This equipment can simultaneously meet the FAA's vertical, horizontal, 45°, and 60° insulated wire combustion test modes and is suitable for flame-retardant performance assessment of non-metallic materials such as aircraft interior trim, seat fabrics, thermal and sound insulation layers, and electrical wires and cables. Whether used for type approval or for quality control during the production process, this combustion chamber is an indispensable core piece of equipment in aerospace materials laboratories.
The Bunsen burner inside the chamber is ignited by an automatic ignition device, and the flame is precisely applied to the material sample in the sample holder according to a set time. The system automatically records the afterflame time, dripping time, and damage distance, thereby objectively determining the flame retardancy rating and combustion behavior of the material.
![]()
![]()
| Project | Parameters |
|---|---|
| Test Mode | Vertical / Horizontal / 45° / 60° |
| Burning Time | ≥90s, Accuracy ±0.1s |
| Afterflame/Drip Timing | ≥90s, Accuracy ±0.1s |
| Angle Accuracy | ±0.2° (±0.1° in 60° mode) |
| Methane Outlet Pressure | 17±2 kPa |
| Flame Height (Vertical/Horizontal/45°) | 38±0.1 mm, Center Temperature ≥843℃ |
| Flame Height (60°) | 76.2±0.1 mm, Center Temperature ≥954℃ |
| Thermocouple | Type K, 0.5mm, Temperature Resistance ≥1100℃, Display Accuracy ±0.1℃ |
| Sample Exposure Dimensions | Vertical: 52*356mm; Horizontal: 52*320mm; 45°: 203*203mm |
| Exhaust Port Diameter | φ150mm, Exhaust Volume: 500m³/h |
| Power Requirements | 220V / 50Hz / 0.5kW |
| Environmental conditions | 5~35℃, ≤90%RH, 86~106kPa |